MICA Legionella
MICA Legionella enumerates Legionella pneumophila in water (Domestic Water, Cooling Tower Water, Sanitary Water…) in CFU/liter and after only 48 hours of incubation.
MICA Legionella requires only 1 plate and 4′ of labor time per sample compared to several plates and 25′ on average for the standard ISO 11731:2017 method.
Présentation
Easy
- Result after only 48 hours of incubation
- Automatic enumeration
- User-friendly Interface
- No confirmation required
Cost saving
- Reduction in labor costs : 4′ technician time only per sample against 25′ on average with standard method
- 1 GVPC Plate only per analysis
- No skills required
- Up to 500 tests per 8 hours
Reliable
- Cultural method (CFU/liter)
- Same procedure as ISO 11731:2017
- Detects all serogroups of L. pneumophila
- LOD 1 CFU/L for sanitary water
- LOD 100 CFU/L for cooling tower water
- AOAC Certified
- Evaluated by the European Union (Water Test Network)
Protocol

Step 1
Filtration

Step 2
Culture medium drop on agar

Step 3
Membrane on agar

Step 4
Culture incubation

Step 5
Tagging medium drop

Step 6
Tagging incubation

Step 7
Membrane washing

Step 8
Membrane on cassette

Step 9
Reading of the result
Testimonials
Being able to enumerate this pathogenic bacterium in only two days is a major step forward in the fight against such microbiological risk.
A method very reliable, suitable and comfortable to use for all, and most important a rapid proven test for the enumeration of Legionella pneumophila.
The program is intuitive and really well explained with explanatory videos at key moments of the analysis
Applications
Cooling tower
Contract laboratories
Wastewater
Recreational
Drinking water
Sanitary water
Read more about Legionella
Infectious risk posed by Legionella pneumophila outside of serogroup 1 in hospitals
Infectious risk posed by Legionella pneumophila outside of serogroup 1 in hospitalsDespite existing risk control policies and awareness by health authorities, the diagnosis of legionellosis is still far from systematic.Because hospitalized patients are particularly...
Pontiac Fever, Symptoms, Diagnosis, and Treatments
Pontiac Fever, Symptoms, Diagnosis, and TreatmentsWhat is Pontiac fever? What is the difference between it and Legionnaire’s disease? Why is it called that? How does it manifest? And most importantly, how can it be avoided? C4Hydro revisits this illness. What is...
Pseudomonas, Cryptosporidium, Legionella… What Germs Should You Worry About in Pools and Spas?
Pseudomonas, Cryptosporidium, Legionella… What Germs Should You Worry About in Pools and Spas?The main diseases contracted in pools and spas are caused by about ten pathogenic organisms, including Cryptosporidium, Pseudomonas, Shigella, Legionella, Norovirus, and...
Ready to enhance your quality control management ?
Trust Diamidex for rapid, precise microbial detection & enumeration solutions tailored to your business needs. Don't compromise on safety or efficiency.